Full model and revision are checked before ordering.

Festo CPX-E-CEC-C1-PN 4252741 Controller

Verified technical specifications, selection, installation and commissioning notes for Festo CPX-E-CEC-C1-PN, with Automation engineering and technical-service support.

Model / reference
CPX-E-CEC-C1-PN
Order code
4252741
Manufacturer
Festo SE & Co. KG

Technical data checked: 2026-09-21

Request a current quote.

Pricing, lead time and compatibility review for your quantity and application.

Ask about this exact product.

A short message, model code and one product link.

Ask on WhatsApp

The WhatsApp message includes the product name, model and order code. You can copy the full specifications separately if needed. For image sharing, you choose the app and recipient.

Preview WhatsApp message

Hello, please provide pricing and lead time for this product. Product: Festo CPX-E-CEC-C1-PN 4252741 Controller Model: CPX-E-CEC-C1-PN Order code: 4252741 Product link: https://automation.com.tr/en/urunler/festo-cpx-e-cec-c1-pn/

View full product details

View technical documents (2) ↓

Product overview

Product description and scope of use in one place.

Read the full product description

Festo CPX-E-CEC-C1-PN 4252741 Controller

A DIN-rail CPX-E controller combining CODESYS V3, PROFINET IO and EtherCAT master functionality.

Verified technical specifications, selection, installation and commissioning notes for Festo CPX-E-CEC-C1-PN, with Automation engineering and technical-service support.

Verified technical data

  • Part number: 4252741
  • Product: CPX-E-CEC-C1-PN
  • Mounting: DIN rail
  • Product weight: 288 g
  • Configuration: CODESYS V3; optional CDSB operator unit; GSDML
  • Fieldbus: PROFINET IO / PROFINET RT; LLDP; MRP/MRPD; SNMP
  • Secondary fieldbus: EtherCAT master; CoE / EoE / FoE
  • Ethernet protocols: EasyIP, Modbus TCP, OPC-UA, TCP/IP
  • Ethernet rates: 10 / 100 Mbit/s
  • Nominal electronics/sensor supply: 24 V DC, ±25%
  • Program memory: 100 MB user program
  • Power-failure bridging: 20 ms

Selection criteria

Confirm CODESYS V3, PROFINET IO and EtherCAT master architecture matches the machine. Check address-volume, module count and network topology against the full CPX-E design. Verify 24 VDC PELV supply, current demand and terminal-conductor requirements. Apply IP20 and temperature/mounting-position limits from the exact data sheet.

Installation, commissioning and maintenance

Mount on DIN rail in a protected control cabinet and wire the spring terminal per the official data sheet/manual. Observe PELV, EMC, grounding and network-separation practices. Load the validated CODESYS project and GSDML/network configuration; verify PROFINET and EtherCAT diagnostics. Test I/O, motion/fieldbus communication and machine interlocks before production release. Retain CODESYS project and firmware/configuration backups; inspect DIN-rail seating, terminals, RJ45 links and diagnostic logs.

Source policy: Numeric technical claims are taken only from current official manufacturer sources. No price, stock, lead-time, warranty, distributor or partnership claim is included.

Technical specifications

Product data organized into clear specification groups.

Technical data
Technical data
Part number4252741
ProductCPX-E-CEC-C1-PN
MountingDIN rail
Product weight288 g
ConfigurationCODESYS V3; optional CDSB operator unit; GSDML
FieldbusPROFINET IO / PROFINET RT; LLDP; MRP/MRPD; SNMP
Secondary fieldbusEtherCAT master; CoE / EoE / FoE
Ethernet protocolsEasyIP, Modbus TCP, OPC-UA, TCP/IP
Ethernet rates10 / 100 Mbit/s
Nominal electronics/sensor supply24 V DC, ±25%
Program memory100 MB user program
Power-failure bridging20 ms

Application, selection and use

Open a section to review the details you need.

Applications
  • CODESYS V3 makine kontrolü

  • PROFINET I/O kontrolü

  • EtherCAT master uygulamaları

  • CPX-E dağıtık otomasyon sistemi

Selection criteria
  • Confirm CODESYS V3, PROFINET IO and EtherCAT master architecture matches the machine.

  • Check address-volume, module count and network topology against the full CPX-E design.

  • Verify 24 VDC PELV supply, current demand and terminal-conductor requirements.

  • Apply IP20 and temperature/mounting-position limits from the exact data sheet.

Installation notes
  • Mount on DIN rail in a protected control cabinet and wire the spring terminal per the official data sheet/manual.

  • Observe PELV, EMC, grounding and network-separation practices.

Commissioning
  • Load the validated CODESYS project and GSDML/network configuration; verify PROFINET and EtherCAT diagnostics.

  • Test I/O, motion/fieldbus communication and machine interlocks before production release.

Maintenance / service
  • Retain CODESYS project and firmware/configuration backups; inspect DIN-rail seating, terminals, RJ45 links and diagnostic logs.

Variants / options
  • CPX-E includes controller and bus-node variants; this record is exact CPX-E-CEC-C1-PN part 4252741.

Accessories & compatibility
  • Optional CDSB operator unit

  • Micro SD / USB storage within exact current Festo limits

  • CPX-E I/O modules and compatible terminal strips/connectors

Related product references
  • Festo CPX-E I/O modules

  • Festo CODESYS automation components

  • EtherCAT and PROFINET network components

Alternative product assessment

Festo CPX-E-CEC-C1-PN yerine muadil ancak güncel resmi verilerle elektriksel/mekanik/arayüz/çevresel/fonksiyonel ve gerekiyorsa emniyet/Ex eşdeğerliği kanıtlanırsa değerlendirilir. Marka/seri benzerliği tek başına yeterli değildir.

Technical documents

Open data sheets and manufacturer sources. Links open in a new tab.

Frequently asked questions

Festo CPX-E-CEC-C1-PN hangi uygulamalarda kullanılır?

Başlıca kullanım alanları: CODESYS V3 makine kontrolü, PROFINET I/O kontrolü, EtherCAT master uygulamaları, CPX-E dağıtık otomasyon sistemi. Nihai seçim gerçek saha koşullarıyla doğrulanmalıdır.

Teknik değerlerin kaynağı nedir?

Teknik değerler güncel resmi üretici kaynağından doğrulandı: https://ftp.festo.com/public/PNEUMATIC/SOFTWARE_SERVICE/DataSheet/EN_GB/4252741.pdf

Muadil ürün kullanılabilir mi?

Muadil yalnız elektriksel, mekanik, haberleşme, çevresel, fonksiyonel ve gerekiyorsa emniyet/Ex şartları resmi verilerle eşdeğer olduğunda değerlendirilmelidir.

Montaj öncesi ne doğrulanmalı?

Besleme, arayüz, mekanik ölçüler, çevresel koşullar, bağlantı standardı ve üreticinin güncel talimatları doğrulanmalıdır.

Automation hangi desteği sağlar?

Teknik ürün seçimi, uygulama değerlendirmesi, entegrasyon, devreye alma ve endüstriyel teknik servis için proje bazlı destek ve teklif süreci yürütülebilir.

Related industries & technical tags

Industries

Attributes

Tags

Technical verification note

Before ordering, confirm application suitability, safety functions, connections and revision differences against the exact product code and manufacturer documentation.

TECHNICAL QUOTATION

Let’s discuss this product.

The product is linked automatically. Share your quantity, application and required date.

Product for quotation Festo CPX-E-CEC-C1-PN 4252741 Kontrolör · CPX-E-CEC-C1-PN
CPX-E-CEC-C1-PNRequest quote ↗
AUTOMATION / COMPARE

Compare products

Stored specifications are shown side by side, without asserting equivalence or compatibility. Up to 100 fields are shown; check the product page for complete data.

TECHNICAL SOURCING REQUEST

Your quote list

Collect products and quantities. Pricing and lead time are provided after reviewing your request. Your list is stored in this browser.

Continue to quote form →