The Core i5-based AC810 can be evaluated for multi-axis machines using two EtherCAT masters and CODESYS-based development. A01 specifies 128 axes in its technical table, but a different performance statement requires project-level confirmation.
Technical specifications
| CPU | Intel Core i5 / 2.5 GHz |
|---|---|
| Supply | 24 V DC ±20% |
| EtherCAT masters | 2 |
| Maximum axes | 128 |
| Performance reference | 32 axes / 500 µs |
| Development | InoProShop / CODESYS |
| Serial ports | RS232 / RS485 |
| Protection | IP20 |
| Cooling | 2 fans |
| Ethernet protocols | OPC UA / Modbus TCP / EtherNet/IP |
The A01 AC810 column is used. Maximum axes do not guarantee cycle time; test CPU, I/O and communication workload together. The same flyer also mentions 256 axes/4 ms; confirm capacity before ordering.
Application selection
Test target cycle, axis count and I/O workload together.
Will 128 axes always operate at a 500-microsecond cycle?
No. The 500 µs reference concerns 32 axes and is not the maximum-axis operating condition.
Installation and commissioning
Qualified personnel must use the exact-model manual for installation and commissioning. Apply lockout before physical inspection, retain project/parameter backups and never bypass protective functions.
Quotation and supply
Send the axis structure and cycle target for a controller offer.
Price, stock and lead time are not verified and require confirmation in the quotation.
Product comparison
H3U-1616MT-XP-INT – Separate model; not an automatic substitute.
Manufacturer-assigned product/enclosure visual. A separate full-code nameplate is unverified; some models share the image.