The 27 A P model can be compared for large drum axes retaining pulse/CAN at three-phase 200–240 V. This non-FS code requires separate consideration of safe stopping hardware.
Technical specifications
| Supply class | 3 phase 200-240 V AC |
|---|---|
| Continuous output current | 27 A |
| Peak output current | 67.5 A |
| Command interface | Pulse / CANopen / CANlink |
| STO | No FS: not fitted |
| Digital channels | 8 DI / 5 DO |
| Analogue channels | 2 AI / 1 AO |
| PC interface | USB-C |
| Frame | E |
| Mass | 3.60 kg |
A01 ordering and selection charts are used. Verify supply phase, FS option and motor pairing by full code; peak current is not a continuous rating.
Application selection
Distinguish full-drum inertia from the empty-running load.
Does greater current capacity automatically solve regeneration demand?
No. Deceleration energy and the braking arrangement need separate calculation.
Installation and commissioning
Qualified personnel must use the exact-model manual for installation and commissioning. Apply lockout before physical inspection, retain project/parameter backups and never bypass protective functions.
Quotation and supply
Share drum capacity and the installed command method for a scoped offer.
Price, stock and lead time are not verified and require confirmation in the quotation.
Product comparison
SV670PS022I-INT – Separate model; not an automatic substitute.
Manufacturer-assigned product/enclosure visual. A separate full-code nameplate is unverified; some models share the image.