The 26 A P variant suits evaluation where a high-current axis must retain pulse or CAN commands. This ordering code has no FS suffix, so the machine stopping architecture needs separate consideration.
Technical specifications
| Supply class | 3 phase 380-480 V AC |
|---|---|
| Continuous output current | 26 A |
| Peak output current | 65 A |
| Command interface | Pulse / CANopen / CANlink |
| STO | No FS: not fitted |
| Digital channels | 8 DI / 5 DO |
| Analogue channels | 2 AI / 1 AO |
| PC interface | USB-C |
| Frame | E |
| Mass | 3.60 kg |
A01 ordering and selection charts are used. Verify supply phase, FS option and motor pairing by full code; peak current is not a continuous rating.
Application selection
Compare controller pulse capacity with required speed and electronic gearing.
May built-in STO be assumed for this code?
No. STO is not assumed to be included in the version without FS.
Installation and commissioning
Qualified personnel must use the exact-model manual for installation and commissioning. Apply lockout before physical inspection, retain project/parameter backups and never bypass protective functions.
Quotation and supply
Share the controller output type for an interface-matched quotation.
Price, stock and lead time are not verified and require confirmation in the quotation.