Stationary bar code reader | 50120786
Leuze BCL 358i SM 100 D H (50120786) is a stationary bar code reader. Series: BCL 300i; Functions: Alignment mode AutoConfig AutoControl AutoReflAct Code fragment technology Heating LED indicator Reference code comparison; Code types, readable: 2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 GS1 Databar Expanded GS1 Databar Limited GS1 Databar Omnidirectional UPC.
Technical specifications
Basic data
Functions
| Functions |
Alignment mode AutoConfig AutoControl AutoReflAct Code fragment technology Heating LED indicator Reference code comparison |
Read data
| Code types, readable |
2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 GS1 Databar Expanded GS1 Databar Limited GS1 Databar Omnidirectional UPC |
| Scanning rate, typical |
1,000 scans/s |
| Bar codes per reading gate, max. number |
64 Piece(s) |
Optical data
| Reading distance |
30 … 290 mm |
| Light source |
Laser, Red |
| Wavelength |
655 nm |
| Laser class |
1, IEC/EN 60825-1:2014 |
| Modulus size |
0.2 … 0.5 mm |
| Reading method |
Line scanner with deflecting mirror |
| Beam deflection |
By means of rotating polygon mirror wheel + deflecting mirror |
| Light beam exit |
Lateral with deflecting mirror |
Electrical data
| Supply voltage U B |
18 … 30 V, DC |
| Power consumption, max. |
27 W |
| Number of inputs/outputs selectable |
2 Piece(s) |
| Input current, max. |
8 mA |
Performance data
| Supply voltage U B |
18 … 30 V, DC |
| Power consumption, max. |
27 W |
Inputs/outputs selectable
| Number of inputs/outputs selectable |
2 Piece(s) |
| Input current, max. |
8 mA |
Interface
| Type |
EtherNet IP |
| Address assignment |
DHCP Manual address assignment |
| Function |
Process |
| Switch functionality |
Integrated |
EtherNet IP
| Address assignment |
DHCP Manual address assignment |
| Function |
Process |
| Switch functionality |
Integrated |
Service interface
| Type |
USB 2.0 |
| Function |
Configuration via software |
USB
| Function |
Configuration via software |
Connection
| Number of connections |
1 Piece(s) |
| Function |
BUS IN Connection to device Data interface PWR / SW IN / OUT Service interface |
| Type of connection |
Plug connector, It is essential to use a connection unit when commissioning the device. |
| No. of pins |
32 -pin |
| Type |
Male |
Connection 1
| Function |
BUS IN Connection to device Data interface PWR / SW IN / OUT Service interface |
| Type of connection |
Plug connector, It is essential to use a connection unit when commissioning the device. |
| No. of pins |
32 -pin |
| Type |
Male |
Mechanical data
| Design |
Cubic |
| Dimension (W x H x L) |
103 mm x 44 mm x 96 mm |
| Housing material |
Metal |
| Metal housing |
Diecast aluminum |
| Lens cover material |
Glass |
| Net weight |
350 g |
| Housing color |
Red Silver |
| Type of fastening |
Dovetail grooves Fastening on back Via optional mounting device |
Operation and display
| Type of display |
LED Monochromatic graphic display, 128 x 32 pixels |
| Number of LEDs |
2 Piece(s) |
| Type of configuration |
Via web browser |
Environmental data
| Ambient temperature, operation |
-35 … 40 °C |
| Ambient temperature, storage |
-20 … 70 °C |
| Relative humidity (non-condensing) |
0 … 90 % |
Certifications
| Degree of protection |
IP 65 |
| Protection class |
III |
| Approvals |
c UL US |
| Test procedure for EMC in accordance with standard |
EN 55022 EN 61000-4-2, -3, -4, -6 |
| Test procedure for shock in accordance with standard |
IEC 60068-2-27, test Ea |
| Test procedure for continuous shock in accordance with standard |
IEC 60068-2-29, test Eb |
| Test procedure for vibration in accordance with standard |
IEC 60068-2-6, test Fc |
Classification
| Customs tariff number |
84719000 |
| ECLASS 5.1.4 |
27280102 |
| ECLASS 8.0 |
27280102 |
| ECLASS 9.0 |
27280102 |
| ECLASS 10.0 |
27280102 |
| ECLASS 11.0 |
27280102 |
| ECLASS 12.0 |
27280102 |
| ECLASS 13.0 |
27280102 |
| ECLASS 14.0 |
27280102 |
| ECLASS 15.0 |
27280102 |
| ECLASS 16.0 |
27280102 |
| ETIM 5.0 |
EC002550 |
| ETIM 6.0 |
EC002550 |
| ETIM 7.0 |
EC002550 |
| ETIM 8.0 |
EC002550 |
| ETIM 9.0 |
EC002550 |
| ETIM 10.0 |
EC002550 |
| UNSPSC 26.08 |
43211701 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50120786 official product record.