Stationary bar code reader | 50122782
Leuze BCL 558i SF 102 H (50122782) is a stationary bar code reader. Series: BCL 500i; Functions: Alignment mode AutoConfig AutoControl AutoReflAct Code fragment technology Heating LED indicator Reference code comparison; Code types, readable: 2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 EAN 128 EAN Addendum GS1 Databar Expanded GS1 Databar Limited GS1 Databar Omnidirectional UPC.
Technical specifications
Basic data
Functions
| Functions |
Alignment mode AutoConfig AutoControl AutoReflAct Code fragment technology Heating LED indicator Reference code comparison |
Read data
| Code types, readable |
2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 EAN 128 EAN Addendum GS1 Databar Expanded GS1 Databar Limited GS1 Databar Omnidirectional UPC |
| Scanning rate, typical |
1,000 scans/s |
| Bar codes per reading gate, max. number |
64 Piece(s) |
Optical data
| Reading distance |
400 … 1,600 mm |
| Light source |
Laser, Red |
| Wavelength |
650 nm |
| Laser class |
1, IEC/EN 60825-1:2014 |
| Modulus size |
0.5 … 1 mm |
| Reading method |
Line scanner |
| Scanning rate |
800 … 1,200 scans/s |
| Beam deflection |
Via rotating polygon wheel |
| Light beam exit |
Front |
Electrical data
| Supply voltage U B |
10 … 30 V, DC |
| Power consumption, max. |
11 W |
| Number of inputs/outputs selectable |
4 Piece(s) |
| Input current, max. |
8 mA |
Performance data
| Supply voltage U B |
10 … 30 V, DC |
| Power consumption, max. |
11 W |
Inputs/outputs selectable
| Number of inputs/outputs selectable |
4 Piece(s) |
| Input current, max. |
8 mA |
Interface
| Type |
EtherNet IP |
| Address assignment |
DHCP Manual address assignment |
| Function |
Process |
| Switch functionality |
Integrated |
EtherNet IP
| Address assignment |
DHCP Manual address assignment |
| Function |
Process |
| Switch functionality |
Integrated |
Service interface
| Type |
USB |
| Function |
Configuration via software Service |
USB
| Function |
Configuration via software Service |
Connection
| Number of connections |
5 Piece(s) |
| Function |
BUS OUT |
| Type of connection |
Connector |
| Designation on device |
BUS OUT |
| Connector type |
USB 2.0 Standard-A |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Connection 1
| Function |
Service interface |
| Type of connection |
USB |
| Designation on device |
SERVICE |
| Connector type |
USB 2.0 Standard-A |
Connection 2
| Function |
Signal OUT |
| Type of connection |
Connector |
| Designation on device |
SW IN/OUT |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
5 -pin |
| Encoding |
A-coded |
Connection 3
| Function |
Signal IN Signal OUT Voltage supply |
| Type of connection |
Connector |
| Designation on device |
PWR |
| Thread size |
M12 |
| Type |
Male |
| Material |
Metal |
| No. of pins |
5 -pin |
| Encoding |
A-coded |
Connection 4
| Function |
BUS IN |
| Type of connection |
Connector |
| Designation on device |
HOST / BUS IN |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Connection 5
| Function |
BUS OUT |
| Type of connection |
Connector |
| Designation on device |
BUS OUT |
| Thread size |
M12 |
| Type |
Female |
| No. of pins |
4 -pin |
Mechanical data
| Design |
Cubic |
| Dimension (W x H x L) |
123.5 mm x 63 mm x 106.5 mm |
| Housing material |
Metal |
| Metal housing |
Aluminum |
| Lens cover material |
Glass |
| Net weight |
1,100 g |
| Housing color |
Red Silver |
| Type of fastening |
Dovetail grooves Mounting thread Via optional mounting device |
Operation and display
| Type of display |
LED Monochromatic graphical display, 128×64 pixel, with background lighting |
| Number of LEDs |
2 Piece(s) |
| Type of configuration |
Via web browser |
| Operational controls |
Button(s) |
Environmental data
| Ambient temperature, operation |
-35 … 40 °C |
| Ambient temperature, storage |
-20 … 70 °C |
| Relative humidity (non-condensing) |
90 % |
Certifications
| Degree of protection |
IP 65 |
| Protection class |
III |
| Approvals |
c UL US |
| Test procedure for EMC in accordance with standard |
EN 55022 EN 61000-4-2, -3, -4, -6 |
| Test procedure for shock in accordance with standard |
IEC 60068-2-27, test Ea |
| Test procedure for continuous shock in accordance with standard |
IEC 60068-2-29, test Eb |
| Test procedure for vibration in accordance with standard |
IEC 60068-2-6, test Fc |
Classification
| Customs tariff number |
84719000 |
| ECLASS 5.1.4 |
27280102 |
| ECLASS 8.0 |
27280102 |
| ECLASS 9.0 |
27280102 |
| ECLASS 10.0 |
27280102 |
| ECLASS 11.0 |
27280102 |
| ECLASS 12.0 |
27280102 |
| ECLASS 13.0 |
27280102 |
| ECLASS 14.0 |
27280102 |
| ECLASS 15.0 |
27280102 |
| ECLASS 16.0 |
27280102 |
| ETIM 5.0 |
EC002550 |
| ETIM 6.0 |
EC002550 |
| ETIM 7.0 |
EC002550 |
| ETIM 8.0 |
EC002550 |
| ETIM 9.0 |
EC002550 |
| ETIM 10.0 |
EC002550 |
| UNSPSC 26.08 |
43211701 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50122782 official product record.