Stationary bar code reader | 50129661
Leuze BCL 900i SN 102 (50129661) is a stationary bar code reader. Series: BCL 900i; Functions: Alignment mode AutoConfig Code fragment technology LED indicator; Code types, readable: 2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 EAN 128 EAN Addendum UPC.
Technical specifications
Basic data
Functions
| Functions |
Alignment mode AutoConfig Code fragment technology LED indicator |
Read data
| Code types, readable |
2/5 Interleaved Codabar Code 39 Code 93 Code 128 EAN 8/13 EAN 128 EAN Addendum UPC |
| Scanning rate, typical |
1,000 scans/s |
Optical data
| Reading distance |
525 … 1,500 mm |
| Light source |
Laser, Red |
| Wavelength |
650 nm |
| Laser class |
2, IEC/EN 60825-1:2007 |
| Modulus size |
0.25 … 0.38 mm |
| Reading method |
Line scanner |
| Scanning rate |
1,000 scans/s |
| Beam deflection |
Via rotating polygon wheel |
| Light beam exit |
Front |
Electrical data
| Supply voltage U B |
10 … 30 V, DC |
| Power consumption, max. |
10 W |
| Number of digital switching inputs |
3 Piece(s) |
| Function |
Encoder input |
| Number of digital switching outputs |
2 Piece(s) |
Performance data
| Supply voltage U B |
10 … 30 V, DC |
| Power consumption, max. |
10 W |
Inputs
| Number of digital switching inputs |
3 Piece(s) |
| Function |
Encoder input |
Digital switching input 3
Outputs
| Number of digital switching outputs |
2 Piece(s) |
Interface
| Type |
Ethernet, RS 232, RS 422 |
| Function |
Process Service |
| Transmission protocol |
TCP/IP , UDP |
| Architecture |
Client Server |
| Address assignment |
DHCP |
| Switch functionality |
Integrated |
RS 232
| Function |
Process |
| Transmission protocol |
Adjustable |
RS 422
| Function |
Process |
| Transmission protocol |
Adjustable |
Ethernet
| Architecture |
Client Server |
| Address assignment |
DHCP |
| Function |
Process Service |
| Switch functionality |
Integrated |
| Transmission protocol |
TCP/IP , UDP |
Connection
| Number of connections |
4 Piece(s) |
| Function |
Data interface |
| Type of connection |
Connector |
| Designation on device |
ETH2 |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Connection 1
| Function |
Voltage supply |
| Type of connection |
Connector |
| Designation on device |
POWER |
| Thread size |
M12 |
| Type |
Male |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
A-coded |
Connection 2
| Function |
Internal communication interface |
| Type of connection |
Connector |
| Designation on device |
I/O |
| Thread size |
M12 |
| Type |
Male |
| Material |
Metal |
| No. of pins |
17 -pin |
| Encoding |
A-coded |
Connection 3
| Function |
Data interface |
| Type of connection |
Connector |
| Designation on device |
ETH1 |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Connection 4
| Function |
Data interface |
| Type of connection |
Connector |
| Designation on device |
ETH2 |
| Thread size |
M12 |
| Type |
Female |
| Material |
Metal |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Mechanical data
| Design |
Cubic |
| Dimension (W x H x L) |
216 mm x 96 mm x 127 mm |
| Housing material |
Metal |
| Metal housing |
Diecast aluminum |
| Lens cover material |
Glass |
| Net weight |
2,000 g |
| Housing color |
Red Silver |
| Type of fastening |
Via optional mounting device |
Operation and display
| Type of display |
LED |
| Number of LEDs |
5 Piece(s) |
| Type of configuration |
Via web browser |
| Operational controls |
Button(s) |
Environmental data
| Ambient temperature, operation |
0 … 50 °C |
| Ambient temperature, storage |
-20 … 70 °C |
| Relative humidity (non-condensing) |
0 … 90 % |
Certifications
| Degree of protection |
IP 65 |
| Approvals |
c CSA US |
| Test procedure for EMC in accordance with standard |
EN 55022 EN 61000-4-2, -3, -4, -6 |
| Test procedure for shock in accordance with standard |
IEC 60068-2-27, test Ea |
| Test procedure for continuous shock in accordance with standard |
IEC 60068-2-29, test Eb |
| Test procedure for vibration in accordance with standard |
IEC 60068-2-6, test Fc |
Classification
| Customs tariff number |
84719000 |
| ECLASS 5.1.4 |
27280102 |
| ECLASS 8.0 |
27280102 |
| ECLASS 9.0 |
27280102 |
| ECLASS 10.0 |
27280102 |
| ECLASS 11.0 |
27280102 |
| ECLASS 12.0 |
27280102 |
| ECLASS 13.0 |
27280102 |
| ECLASS 14.0 |
27280102 |
| ECLASS 15.0 |
27280102 |
| ECLASS 16.0 |
27280102 |
| ETIM 5.0 |
EC002550 |
| ETIM 6.0 |
EC002550 |
| ETIM 7.0 |
EC002550 |
| ETIM 8.0 |
EC002550 |
| ETIM 9.0 |
EC002550 |
| ETIM 10.0 |
EC002550 |
| UNSPSC 26.08 |
43211701 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50129661 official product record.