Optical data transmission | 50134435
Leuze DDLS 548i 120.3 L H (50134435) is a optical data transmission. Series: DDLS 500; Special version: Heating Integrated laser alignment aid Not influenced by reflective surfaces Operation of parallel light axes Remote diagnosis via web server; Working range: 100 … 120,000 mm.
Technical specifications
Basic data
Special version
| Special version |
Heating Integrated laser alignment aid Not influenced by reflective surfaces Operation of parallel light axes Remote diagnosis via web server |
Optical data
| Working range |
100 … 120,000 mm |
| Light source |
Laser, Infrared |
| Transmission frequency |
F3 |
| Opening angle |
1 ° |
Electrical data
| Supply voltage U B |
18 … 30 V, DC |
Performance data
| Supply voltage U B |
18 … 30 V, DC |
Interface
| Transmission protocol |
CIPsafety PROFINET/PROFIsafe PROFINET slave network device |
| Type |
PROFINET, PROFIsafe over PROFINET |
| Function |
Process |
| Conformance class |
B |
| Switch functionality |
None |
| Transmission speed |
100 Mbit/s |
PROFINET
| Function |
Process |
| Conformance class |
B |
| Switch functionality |
None |
| Transmission speed |
100 Mbit/s |
Connection
| Number of connections |
2 Piece(s) |
| Type of connection |
Connector |
| Designation on device |
BUS |
| Thread size |
M12 |
| Type |
Female |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Connection 1
| Type of connection |
Connector |
| Designation on device |
POWER |
| Thread size |
M12 |
| Type |
Male |
| No. of pins |
5 -pin |
| Encoding |
A-coded |
Connection 2
| Type of connection |
Connector |
| Designation on device |
BUS |
| Thread size |
M12 |
| Type |
Female |
| No. of pins |
4 -pin |
| Encoding |
D-coded |
Mechanical data
| Dimension (W x H x L) |
100 mm x 156 mm x 99.5 mm |
| Housing material |
Metal |
| Net weight |
1,255 g |
Operation and display
| Type of display |
Bar graph LED |
| Type of configuration |
GSDML file Software Via web browser |
Environmental data
| Ambient temperature, operation |
-35 … 50 °C |
| Ambient temperature, storage |
-35 … 70 °C |
Certifications
| Degree of protection |
IP 65 |
| Approvals |
c UL US |
| Test procedure for EMC in accordance with standard |
EN 1000-6-4 EN 61000-6-2 |
| Test procedure for noise in accordance with standard |
EN 60068-2-64 |
| Test procedure for oscillation in accordance with standard |
EN 60068-2-6 |
| Test procedure for shock in accordance with standard |
EN 60068-2-27 |
Classification
| Customs tariff number |
84718000 |
| ECLASS 5.1.4 |
19039001 |
| ECLASS 8.0 |
19179090 |
| ECLASS 9.0 |
19179090 |
| ECLASS 10.0 |
19170506 |
| ECLASS 11.0 |
19170506 |
| ECLASS 12.0 |
19170506 |
| ECLASS 13.0 |
19170506 |
| ECLASS 14.0 |
19170506 |
| ECLASS 15.0 |
19170506 |
| ECLASS 16.0 |
19170506 |
| ETIM 5.0 |
EC000515 |
| ETIM 6.0 |
EC000515 |
| ETIM 7.0 |
EC000515 |
| ETIM 8.0 |
EC000515 |
| ETIM 9.0 |
EC000515 |
| ETIM 10.0 |
EC000515 |
| UNSPSC 26.08 |
43201544 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50134435 official product record.