Inductive switch | 50114210
Leuze IS 240PP/44-8N0-S8.4 (50114210) is a inductive switch. Series: 240; type. operating range limit S n: 8 mm; Operating range S a: 0 … 6.4 mm.
Technical specifications
Basic data
| Series |
240 |
| type. operating range limit S n |
8 mm |
| Operating range S a |
0 … 6.4 mm |
Special version
| Special version |
Antivalent |
Characteristic parameters
Electrical data
| Protective circuit |
Inductive protection Polarity reversal protection Short circuit protected |
| Supply voltage U B |
10 … 30 V, DC |
| Residual ripple |
0 … 20 %, From U B |
| Open-circuit current |
0 … 10 mA |
| Repeatability, max. (in % of S r ) |
10 %, For U B = 20 … 30 V DC, ambient temperature T a = 23 °C ± 5 °C |
| Switching hysteresis |
5 % |
| Number of digital switching outputs |
2 Piece(s) |
| Voltage type |
DC |
| Switching current, max. |
250 mA |
| Residual current, max. |
0.01 mA |
| Voltage drop |
≤ 2 V |
| Switching element |
Transistor, PNP |
| Switching principle |
NC contact – Antivalent |
Performance data
| Supply voltage U B |
10 … 30 V, DC |
| Residual ripple |
0 … 20 %, From U B |
| Open-circuit current |
0 … 10 mA |
| Repeatability, max. (in % of S r ) |
10 %, For U B = 20 … 30 V DC, ambient temperature T a = 23 °C ± 5 °C |
| Switching hysteresis |
5 % |
Outputs
| Number of digital switching outputs |
2 Piece(s) |
| Voltage type |
DC |
| Switching current, max. |
250 mA |
| Residual current, max. |
0.01 mA |
| Voltage drop |
≤ 2 V |
| Switching element |
Transistor, PNP |
| Switching principle |
NC contact – Antivalent |
Switching outputs
| Voltage type |
DC |
| Switching current, max. |
250 mA |
| Residual current, max. |
0.01 mA |
| Voltage drop |
≤ 2 V |
Switching output 1
| Switching element |
Transistor, PNP |
| Switching principle |
NO contact – Antivalent |
Switching output 2
| Switching element |
Transistor, PNP |
| Switching principle |
NC contact – Antivalent |
Time behavior
| Switching frequency |
1,400 Hz |
| Readiness delay |
300 ms |
Connection
| Number of connections |
1 Piece(s) |
| Function |
Signal OUT Voltage supply |
| Type of connection |
Connector |
| Thread size |
M8 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
4 -pin |
| Encoding |
A-coded |
Connection 1
| Function |
Signal OUT Voltage supply |
| Type of connection |
Connector |
| Thread size |
M8 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
4 -pin |
| Encoding |
A-coded |
Mechanical data
| Design |
Cubic |
| Dimension (W x H x L) |
12 mm x 40 mm x 26 mm |
| Type of installation |
Non-embedded/non-flush |
| Housing material |
Plastic |
| Plastic housing |
PA 66 |
| Sensing face material |
Plastic, Polyamide (PA 66) |
| Net weight |
20 g |
| Housing color |
Black Red, RAL 3000 |
| Type of fastening |
Fastening on back Through-hole mounting |
| Standard measuring plate |
24 x 24 mm², Fe360 |
Operation and display
| Type of display |
LED |
| Number of LEDs |
1 Piece(s) |
Environmental data
| Ambient temperature, operation |
-25 … 70 °C |
| Ambient temperature, storage |
-25 … 70 °C |
Certifications
| Degree of protection |
IP 67 |
| Protection class |
II |
| Approvals |
c UL US |
| Test procedure for EMC in accordance with standard |
IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 |
| Standards applied |
IEC 60947-5-2 |
Correction factors
| Aluminum |
0.4 |
| Stainless steel |
0.8 |
| Copper |
0.45 |
| Brass |
0.55 |
| Fe360 steel |
1 |
Classification
| Customs tariff number |
85365019 |
| ECLASS 5.1.4 |
27270101 |
| ECLASS 8.0 |
27270101 |
| ECLASS 9.0 |
27270101 |
| ECLASS 10.0 |
27270101 |
| ECLASS 11.0 |
27270101 |
| ECLASS 12.0 |
27274001 |
| ECLASS 13.0 |
27274001 |
| ECLASS 14.0 |
27274001 |
| ECLASS 15.0 |
27274001 |
| ECLASS 16.0 |
27274001 |
| ETIM 5.0 |
EC002714 |
| ETIM 6.0 |
EC002714 |
| ETIM 7.0 |
EC002714 |
| ETIM 8.0 |
EC002714 |
| ETIM 9.0 |
EC002714 |
| ETIM 10.0 |
EC002714 |
| UNSPSC 26.08 |
39122230 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50114210 official product record.