Capacitive sensor | 50135739
Leuze LCS-1M30P-F10NNP-M12-LT (50135739) is a capacitive sensor. Series: LCS-1; Switching distance S n (embedded installation): 1 … 10 mm; Switching distance S n (non-embedded installation): 1 … 15 mm.
Technical specifications
Basic data
| Series | LCS-1 |
|---|---|
| Switching distance S n (embedded installation) | 1 … 10 mm |
| Switching distance S n (non-embedded installation) | 1 … 15 mm |
| Assured switching distance (embedded installation) | 7.2 mm |
| Assured switching distance (non-embedded installation) | 10.8 mm |
Electrical data
| Protective circuit | Polarity reversal protection Short circuit protected |
|---|---|
| Supply voltage U B | 10 … 30 V, DC |
| Residual ripple | 0 … 10 %, From U B |
| Open-circuit current | 15 mA |
| Temperature drift, max. (in % of S r ) | 20 % |
| Repeatability, max. (in % of S r ) | 2 % |
| Rated operating current | 200 mA |
| Number of digital switching outputs | 1 Piece(s) |
| Type | Digital switching output |
| Voltage type | DC |
| Switching element | Transistor, NPN |
| Switching principle | Normally closed contact (NC)/normally open contact (NO), programmable |
Performance data
| Supply voltage U B | 10 … 30 V, DC |
|---|---|
| Residual ripple | 0 … 10 %, From U B |
| Open-circuit current | 15 mA |
| Temperature drift, max. (in % of S r ) | 20 % |
| Repeatability, max. (in % of S r ) | 2 % |
| Rated operating current | 200 mA |
Outputs
| Number of digital switching outputs | 1 Piece(s) |
|---|---|
| Type | Digital switching output |
| Voltage type | DC |
| Switching element | Transistor, NPN |
| Switching principle | Normally closed contact (NC)/normally open contact (NO), programmable |
Switching outputs
| Type | Digital switching output |
|---|---|
| Voltage type | DC |
Switching output 1
| Switching element | Transistor, NPN |
|---|---|
| Switching principle | Normally closed contact (NC)/normally open contact (NO), programmable |
Time behavior
| Switching frequency | 10 Hz |
|---|
Interface
| Type | IO-Link |
|---|---|
| COM mode | COM2 |
| Frame type | 2.2 |
| Specification | 1.1 |
IO-Link
| COM mode | COM2 |
|---|---|
| Frame type | 2.2 |
| Specification | 1.1 |
Connection
| Number of connections | 1 Piece(s) |
|---|---|
| Function | Signal OUT Voltage supply |
| Type of connection | Connector |
| Thread size | M12 |
| Type | Male |
| Material | Plastic |
| No. of pins | 5 -pin |
| Encoding | A-coded |
Connection 1
| Function | Signal OUT Voltage supply |
|---|---|
| Type of connection | Connector |
| Thread size | M12 |
| Type | Male |
| Material | Plastic |
| No. of pins | 5 -pin |
| Encoding | A-coded |
Mechanical data
| Design | Cylindrical |
|---|---|
| Dimension (Ø x L) | 30 mm x 87.3 mm |
| Thread size | M30 x 1.5 mm |
| Type of installation | Embedded/flush |
| Housing material | Plastic |
| Plastic housing | Polyamide (PA 12) |
| Sensing face material | Plastic, Polyamide (PA 12) |
| Cover material | Plastic, Polyamide (PA 12) |
| Net weight | 67 g |
Operation and display
| Type of display | LED |
|---|---|
| Number of LEDs | 1 Piece(s) |
| Operational controls | Teach button |
| Switching distance, adjustable | Yes |
Environmental data
| Ambient temperature, operation | -25 … 70 °C |
|---|
Certifications
| Degree of protection | IP 67 |
|---|---|
| Protection class | III |
| Approvals | c UL US |
| Standards applied | IEC 60947-5-2 |
Classification
| Customs tariff number | 85365019 |
|---|---|
| ECLASS 5.1.4 | 27270102 |
| ECLASS 8.0 | 27270102 |
| ECLASS 9.0 | 27270102 |
| ECLASS 10.0 | 27270102 |
| ECLASS 11.0 | 27270102 |
| ECLASS 12.0 | 27274201 |
| ECLASS 13.0 | 27274201 |
| ECLASS 14.0 | 27274201 |
| ECLASS 15.0 | 27274201 |
| ECLASS 16.0 | 27274201 |
| ETIM 5.0 | EC002715 |
| ETIM 6.0 | EC002715 |
| ETIM 7.0 | EC002715 |
| ETIM 8.0 | EC002715 |
| ETIM 9.0 | EC002715 |
| ETIM 10.0 | EC002715 |
| UNSPSC 26.08 | 39122230 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50135739 official product record.