Protective field matched to the opening
MLC510R40-2850 is a Basic safety light curtain receiver with a 2850 mm nominal protective field and 40 mm resolution. It is a receiver component, not a complete transmitter–receiver set. Plan the optical pair, mounting arrangement and safety-related control interface together before using order code 68001428 for a project.
Resolution and placement
A 40 mm resolution may be considered for hand or danger-zone guarding only after the installation geometry has been assessed. Mounting orientation and access routes remain part of the project evaluation. The long housing requires particular attention to straight mounting, alignment and access around the protected field. Its nominal sensing height is not a guarantee that every approach route is covered.
Response time belongs in the machine calculation
This receiver has a 25 ms response time and two PNP OSSD safety outputs. Include receiver response, safety-controller delay and measured machine stopping time when establishing the required separation distance. The total profile size is 29 × 2916 × 35.4 mm.
Basic function package and commissioning
The Basic receiver uses automatic start/restart and selectable transmission channels. Type 4, PL e and SIL 3 identify the sensor class; they are not a certificate for the complete machine. A suitable external restart interlock or protection against standing behind the field is essential where the risk assessment requires it. Wiring, validation and periodic checks must be performed by competent personnel.
Image note: The manufacturer’s Basic receiver series photograph is illustrative; physical length varies by model.
Request an Automation quotation for MLC510R40-2850. Include order code 68001428, quantity, opening dimensions and the intended safety-control interface.