Optical distance sensor | 50138327
Leuze ODS9L2.8/LFH-450-M12 (50138327) is a optical distance sensor. Series: 9; Type of scanning system: Against object; MTTF: 36 years.
Technical specifications
Basic data
| Series |
9 |
| Type of scanning system |
Against object |
Characteristic parameters
Optical data
| Beam path |
Divergent |
| Light source |
Laser, Red |
| Wavelength |
655 nm |
| Laser class |
2, IEC/EN 60825-1:2014 |
| Transmitted-signal shape |
Pulsed |
| Light spot size [at sensor distance] |
1 mm [450 mm] |
| Type of light spot geometry |
Round |
Measurement data
| Measurement range |
50 … 450 mm |
| Resolution |
0.1 mm |
| Accuracy |
1 % |
| Reference value, accuracy |
Measurement distance |
| Reproducibility (1 sigma) |
0.1 mm |
| Temperature drift |
0.02 %/K |
| Referencing |
No |
| Optical distance measurement principle |
Triangulation |
Electrical data
| Protective circuit |
Polarity reversal protection Short circuit protected Transient protection |
| Supply voltage U B |
10 … 30 V, DC |
| Number of digital switching outputs |
1 Piece(s) |
| Type |
Digital switching output |
| Switching element |
Transistor, Push-pull |
Performance data
| Supply voltage U B |
10 … 30 V, DC |
Outputs
| Number of digital switching outputs |
1 Piece(s) |
| Type |
Digital switching output |
| Switching element |
Transistor, Push-pull |
Switching outputs
| Type |
Digital switching output |
Switching output 1
| Switching element |
Transistor, Push-pull |
Time behavior
| Response time |
1 ms, Under constant ambient conditions, 90% diffuse reflection, standard measure mode |
| Readiness delay |
300 ms |
Interface
| Type |
IO-Link, RS 232 |
| COM mode |
COM3 |
| Profile |
Smart sensor profile |
| Min. cycle time |
COM3 = 0.5 ms |
| Frame type |
2.V |
| Port type |
A |
| Specification |
V1.1 |
| Device ID |
2186 |
| SIO-mode support |
Yes |
| Process data IN |
4 byte |
| Process data OUT |
8 bit |
| Dual Channel |
Yes |
IO-Link
| COM mode |
COM3 |
| Profile |
Smart sensor profile |
| Min. cycle time |
COM3 = 0.5 ms |
| Frame type |
2.V |
| Port type |
A |
| Specification |
V1.1 |
| Device ID |
2186 |
| SIO-mode support |
Yes |
| Process data IN |
4 byte |
| Process data OUT |
8 bit |
| Dual Channel |
Yes |
Connection
| Number of connections |
1 Piece(s) |
| Function |
Signal OUT Voltage supply |
| Type of connection |
Connector, Turning, 90° |
| Thread size |
M12 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
5 -pin |
| Encoding |
A-coded |
Connection 1
| Function |
Signal OUT Voltage supply |
| Type of connection |
Connector, Turning, 90° |
| Thread size |
M12 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
5 -pin |
| Encoding |
A-coded |
Mechanical data
| Dimension (W x H x L) |
21 mm x 50 mm x 50 mm |
| Housing material |
Plastic |
| Plastic housing |
PC |
| Lens cover material |
Glass |
| Net weight |
50 g |
| Housing color |
Red |
| Type of fastening |
Through-hole mounting Via optional mounting device |
Operation and display
| Type of display |
OLED display |
| Number of LEDs |
2 Piece(s) |
| Type of configuration |
Software |
| Operational controls |
Control buttons LC Display PC software |
Environmental data
| Ambient temperature, operation |
-20 … 50 °C |
| Ambient temperature, storage |
-30 … 70 °C |
| Ambient light sensitivity |
20,000 lx, EN 60947-5-2 |
Certifications
| Degree of protection |
IP 67 |
| Protection class |
II |
| Approvals |
c UL US |
| Standards applied |
IEC 60947-5-2 |
Classification
| Customs tariff number |
90318020 |
| ECLASS 5.1.4 |
27270801 |
| ECLASS 8.0 |
27270801 |
| ECLASS 9.0 |
27270801 |
| ECLASS 10.0 |
27270801 |
| ECLASS 11.0 |
27270801 |
| ECLASS 12.0 |
27270916 |
| ECLASS 13.0 |
27270916 |
| ECLASS 14.0 |
27270916 |
| ECLASS 15.0 |
27270916 |
| ECLASS 16.0 |
27270916 |
| ETIM 5.0 |
EC001825 |
| ETIM 6.0 |
EC001825 |
| ETIM 7.0 |
EC001825 |
| ETIM 8.0 |
EC001825 |
| ETIM 9.0 |
EC001825 |
| ETIM 10.0 |
EC001825 |
| UNSPSC 26.08 |
39121528 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.
Technical source: Leuze 50138327 official product record.