Optical distance sensor | 50041204
Leuze ODSL 30/D485-30M-S12 (50041204) is a optical distance sensor. Series: 30; Contains: Mounting brackets; Application: Collision protection of cranes / gantry cranes Fill-level monitoring Length measurement in material cutting Positioning of skillet systems and side-tracking skates.
Technical specifications
Basic data
| Series |
30 |
| Contains |
Mounting brackets |
| Application |
Collision protection of cranes / gantry cranes Fill-level monitoring Length measurement in material cutting Positioning of skillet systems and side-tracking skates |
| Type of scanning system |
Against object |
Optical data
| Beam path |
Collimated |
| Light source |
Laser, Red |
| Wavelength |
655 nm |
| Laser class |
2, IEC/EN 60825-1:2014 |
| Transmitted-signal shape |
Pulsed |
| Light spot size [at sensor distance] |
6 mm [10,000 mm] |
| Type of light spot geometry |
Round |
Measurement data
| Measurement range (6 … 90 % diffuse reflection) |
200 … 30,000 mm |
| Measurement range (90 % diffuse reflection) |
200 … 65,000 mm |
| Resolution |
1.0 mm |
| Accuracy |
2 mm, (+/-) at 90% diffuse reflection / 5 mm (+/-) at 6% diffuse reflection |
| Reproducibility (3 sigma) |
2 mm |
| Temperature drift |
0 … 0.5 mm/K |
| Referencing |
Yes |
| Standard measurement object |
100 x 100 mm² |
| Optical distance measurement principle |
Phase measurement |
Electrical data
| Protective circuit |
Polarity reversal protection Short circuit protected |
| Supply voltage U B |
10 … 30 V, DC |
| Number of digital switching inputs |
2 Piece(s) |
| Type |
Digital switching output |
| Function |
Programmable |
| Number of digital switching outputs |
2 Piece(s) |
| Switching power, max. |
4 W |
| Switching element |
Transistor, Push-pull |
Performance data
| Supply voltage U B |
10 … 30 V, DC |
Inputs
| Number of digital switching inputs |
2 Piece(s) |
| Type |
Digital switching input |
| Function |
Programmable |
Switching inputs
| Type |
Digital switching input |
Digital switching input 1
Digital switching input 2
Outputs
| Number of digital switching outputs |
2 Piece(s) |
| Switching power, max. |
4 W |
| Type |
Digital switching output |
| Switching element |
Transistor, Push-pull |
Switching outputs
| Type |
Digital switching output |
Switching output 1
| Switching element |
Transistor, Push-pull |
Switching output 2
| Switching element |
Transistor, Push-pull |
Time behavior
| Response time |
30 … 100 ms |
| Readiness delay |
1,000 ms |
Interface
Connection
| Number of connections |
1 Piece(s) |
| Function |
Signal IN Signal OUT Voltage supply |
| Type of connection |
Connector |
| Thread size |
M12 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
8 -pin |
| Encoding |
A-coded |
Connection 1
| Function |
Signal IN Signal OUT Voltage supply |
| Type of connection |
Connector |
| Thread size |
M12 |
| Type |
Male |
| Material |
Plastic |
| No. of pins |
8 -pin |
| Encoding |
A-coded |
Mechanical data
| Dimension (W x H x L) |
79 mm x 69 mm x 150 mm |
| Housing material |
Metal |
| Metal housing |
Diecast aluminum |
| Lens cover material |
Glass |
| Net weight |
650 g |
| Housing color |
Gray Silver |
| Type of fastening |
Mounting thread Supplied mounting bracket |
Operation and display
| Type of display |
LC Display LED |
| Operational controls |
LC Display Membrane keyboard |
Environmental data
| Ambient temperature, operation |
0 … 45 °C |
| Ambient temperature, storage |
-40 … 70 °C |
Certifications
| Degree of protection |
IP 67 |
| Protection class |
II |
| Approvals |
c UL US |
| Standards applied |
IEC 60947-5-2 |
Classification
| Customs tariff number |
90318020 |
| ECLASS 5.1.4 |
27270801 |
| ECLASS 8.0 |
27270801 |
| ECLASS 9.0 |
27270801 |
| ECLASS 10.0 |
27270801 |
| ECLASS 11.0 |
27270801 |
| ECLASS 12.0 |
27270916 |
| ECLASS 13.0 |
27270916 |
| ECLASS 14.0 |
27270916 |
| ECLASS 15.0 |
27270916 |
| ECLASS 16.0 |
27270916 |
| ETIM 5.0 |
EC001825 |
| ETIM 6.0 |
EC001825 |
| ETIM 7.0 |
EC001825 |
| ETIM 8.0 |
EC001825 |
| ETIM 9.0 |
EC001825 |
| ETIM 10.0 |
EC001825 |
| UNSPSC 26.08 |
39121528 |
Application and product selection
Evaluate the full model, task, operating range, electrical interface, connection and environmental conditions together.
Installation and commissioning
Qualified personnel should install and wire the device with the machine in a safe, isolated state. Validate operation under actual application conditions.
Maintenance
Inspect active surfaces, connections, cable routing and mounting hardware periodically.
Automation engineering support
Share the exact model, part number and application conditions for product selection, technical supply and commissioning support.