The WhatsApp message includes the product name, model and order code. You can copy the full specifications separately if needed. For image sharing, you choose the app and recipient.
Preview WhatsApp message
Hello, please provide pricing and lead time for this product.
Product: ReeR MOSAIC MO2C Safety automation component
Model: MOSAIC MO2C
Order code: 1100130
Product link:
https://automation.com.tr/en/urunler/reer-mosaic-mo2c-1100130/
Product description and scope of use in one place.
Read the full product description+
Safety automation component | 1100130
ReeR MOSAIC MO2C (1100130): safety automation component. Safety level: PL e; Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4; Operating temperature (°C): – 10 … 55.
Technical specifications
Part number
1100130
Full model
MOSAIC MO2C
Series
MOSAIC
Safety level
PL e
Safety level (SIL / PL)
SIL 3 – SILCL 3 – PL e – Cat. 4
Operating temperature (°C)
– 10 … 55
Signalling
LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs, reset request and status outputs condition
Safety output type
2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections
Removable terminal blocks, clamp contacts
MTTFD (ISO13849) years
30 … 100
PFHD (IEC 61508)
4,09E-09
Safety outputs
2 OSSD pairs (400 mA)
Status outputs
2 PNP (100 mA)
Storage temperature (°C)
-20 … 85
MSC connector provided
Yes
Connection with MSC BUS
Yes
Start/Restart inputs and EDM
2
Power supply (VDC)
24 ± 20%
Dimensions HxWxD (mm)
108 x 22,5 x 114,5
Degree of protection
IP20 for housing – IP2X for terminal block
Fastening
35 mm DIN rail fastening according to EN 50022-35 standard
Selection and application
System integration of documented safety functions. Compare the exact model, electrical interface, mounting and operating environment. Confirm suitability in the actual application.
Documentation
The package includes a bilingual Automation summary and a link to the original ReeR technical source. Numbered notes and operating limits refer to the original source. The manufacturer illustration may differ from the delivered variant.
Quotation
Request a quotation using MOSAIC MO2C, part number 1100130 and quantity. Price, stock and delivery time require confirmation.
02
Technical specifications
Product data organized into clear specification groups.
Product identity+
Product identity
Sipariş kodu
1100130
Tam model
MOSAIC MO2C
Seri
MOSAIC
Teknik özellikler+
Teknik özellikler
Emniyet seviyesi
PL e
Emniyet seviyesi (SIL / PL)
SIL 3 - SILCL 3 - PL e - Cat. 4
Çalışma sıcaklığı (°C)
- 10 ... 55
Sinyalizasyon
LEDs indication for operating status ve fault diagnosis. LED indication of the: OSSD outputs, reset request ve status outputs condition
Emniyet çıkış tipi
2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit, overload ve reverse polarity
Bağlantılar
Removable terminal blocks, clamp contacts
MTTFD (ISO 13849), yıl
30 ... 100
PFHD (IEC 61508)
4,09E-09
Emniyet çıkışları
2 OSSD pairs (400 mA)
Durum çıkışları
2 PNP (100 mA)
Depolama sıcaklığı (°C)
-20 ... 85
MSC konnektör dahil
Evet
MSC BUS bağlantısı
Evet
Başlatma/yeniden başlatma girişleri ve EDM
2
Besleme (VDC)
24 ± 20%
Boyutlar Y×G×D (mm)
108 x 22,5 x 114,5
Koruma derecesi
IP20 for housing - IP2X for terminal block
Sabitleme
35 mm DIN rail fastening according to EN 50022-35 standard
No specifications match. Try another term or clear the search.
03
Application, selection and use
Open a section to review the details you need.
Applications+
Belgelenmiş emniyet işlevlerinin sistem entegrasyonu
Selection criteria+
Tam model, algılama/ölçüm aralığı, çıkış, besleme, bağlantı, montaj ve ortam koşullarını birlikte değerlendirin.
Siparişte MOSAIC MO2C modeli ve 1100130 üretici kodunu birlikte kullanın.
Installation notes+
Montaj, kablolama, pin ataması ve izin verilen montaj mesafeleri için bu modele ait üretici talimatlarını izleyin.
Montaj ve bağlantı işlemlerinden önce ilgili enerji kaynaklarını güvenli biçimde ayırın.
Commissioning+
Ürün etiketini MOSAIC MO2C / 1100130 ile eşleştirin.
Besleme ve çıkış tipini doğruladıktan sonra işlevi gerçek uygulama koşullarında kontrol edin.
Maintenance / service+
Algılama yüzeyi, kablo, bağlantı ve montaj noktalarını periyodik olarak kontrol edin.
Temizlik, değişiklik veya değiştirme sonrasında işlev kontrolü yapın.
Variants / options+
MOSAIC MO2
Order code: 1100030
Aynı seride karşılaştırma referansı. Bağlantılar: MOSAIC MO2C için Removable terminal blocks, clamp contacts; MOSAIC MO2 için Removable terminal blocks, screw contacts. Doğrudan muadil veya uyumluluk beyanı değildir.
Aynı seride karşılaştırma referansı. Emniyet çıkış tipi: MOSAIC MO2C için 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit, overload ve reverse polarity; MOSAIC MO4LHCS8 için 4 single OSSD, or 2 pairs (PNP 2,0 A kanal başına, 8 A total). Doğrudan muadil veya uyumluluk beyanı değildir.
Kablo, karşılık konnektör ve montaj elemanları bu modelin üretici bağlantı/ölçü çizimleriyle eşleştirilmelidir. Belirli bir aksesuar kodu için uyumluluk doğrulanmadığından parça kodu önerilmemiştir.
Before ordering, confirm application suitability, safety functions, connections and revision differences against the exact product code and manufacturer documentation.
TECHNICAL QUOTATION
Let’s discuss this product.
The product is linked automatically. Share your quantity, application and required date.