Full model and revision are checked before ordering.

Schmersal RSS260-I2-D-ST 103003607 RFID Safety Sensor

Model / reference
RSS260-I2-D-ST
Order code
103003607
Manufacturer
K.A. Schmersal GmbH & Co. KG

Technical data checked: 2026-09-21

Pricing and lead time

The part number is included with your enquiry.

Share product details

Ask about this exact product.

A short message, model code and one product link.

Ask on WhatsApp

The WhatsApp message includes the product name, model and order code. You can copy the full specifications separately if needed. For image sharing, you choose the app and recipient.

Preview WhatsApp message

Hello, please provide pricing and lead time for this product. Product: Schmersal RSS260-I2-D-ST 103003607 RFID Safety Sensor Model: RSS260-I2-D-ST Order code: 103003607 Product link: https://automation.com.tr/en/urunler/schmersal-rss260-i2-d-st/

View full product details

View technical documents (2) ↓

Product overview

Read the full product description

Schmersal RSS260-I2-D-ST 103003607 RFID Safety Sensor

A high-coding-level RFID RSS260 safety sensor with 8-pin M8 connection, suitable up to PL e / Category 4 / SIL 3 applications.

Verified technical specifications, selection, installation and commissioning notes for Schmersal RSS260-I2-D-ST, with Automation engineering and technical-service support.

Verified technical data

  • Item number: 103003607
  • Coding: Individual coding, multiple teaching; High per EN ISO 14119
  • RFID frequency: 125 kHz
  • Safe digital outputs: 2
  • Diagnostic output: 1
  • Safety classification: PL e; Category 4; SIL 3
  • PFH: 6.80 × 10⁻¹⁰/h
  • PFD: 1.20 × 10⁻⁴
  • Mission time: 20 years
  • Typical switching distance: 12 mm frontal / 9 mm lateral
  • Connection: M8, 8-pole
  • Operating voltage: 24 VDC -15% / +10%
  • Actuator: Ordered separately

Selection criteria

Perform the machine safety risk assessment and required PL/SIL calculation. Select the actuator and switching distance/orientation using the exact official data. Account for series wiring, voltage drop and external line fusing. Confirm M8 8-pin wiring and diagnostic strategy.

Installation, commissioning and maintenance

Use two M4 fixing screws and respect the official maximum tightening torque. Maintain the required sensor/actuator alignment and minimum clearances; actuator is not included. Teach/coding procedure and all guard positions must be validated before release. Test both safety outputs, diagnostics and fault response within the complete safety function. Periodically inspect alignment, actuator/sensor mounting, cable/connector integrity and safety diagnostic faults; proof-test per machine safety plan.

Source policy: Numeric technical claims are taken only from current official manufacturer sources. No price, stock, lead-time, warranty, distributor or partnership claim is included.

Technical specifications

Product data organized into clear specification groups.

Technical data
Technical data
Item number103003607
CodingIndividual coding, multiple teaching; High per EN ISO 14119
RFID frequency125 kHz
Safe digital outputs2
Diagnostic output1
Safety classificationPL e; Category 4; SIL 3
PFH6.80 × 10⁻¹⁰/h
PFD1.20 × 10⁻⁴
Mission time20 years
Typical switching distance12 mm frontal / 9 mm lateral
ConnectionM8, 8-pole
Operating voltage24 VDC -15% / +10%
ActuatorOrdered separately

Application, selection and use

Open a section to review the details you need.

Applications
  • Koruyucu kapı konum izleme

  • Seri bağlı emniyet sensör zinciri

  • Manipülasyona dayanıklı RFID emniyet algılama

  • Makine koruyucu interlock izleme

Selection criteria
  • Perform the machine safety risk assessment and required PL/SIL calculation.

  • Select the actuator and switching distance/orientation using the exact official data.

  • Account for series wiring, voltage drop and external line fusing.

  • Confirm M8 8-pin wiring and diagnostic strategy.

Installation notes
  • Use two M4 fixing screws and respect the official maximum tightening torque.

  • Maintain the required sensor/actuator alignment and minimum clearances; actuator is not included.

Commissioning
  • Teach/coding procedure and all guard positions must be validated before release.

  • Test both safety outputs, diagnostics and fault response within the complete safety function.

Maintenance / service
  • Periodically inspect alignment, actuator/sensor mounting, cable/connector integrity and safety diagnostic faults; proof-test per machine safety plan.

Variants / options
  • RSS260 coding/output variants differ; this record is exact I2-D-ST, item 103003607.

Accessories & compatibility
  • Recommended actuators: RST-U-2, RST16-1, RST260-1

  • Compatible Schmersal SRB-E / PSC1 safety evaluation components where application design requires them

Related product references
  • Schmersal RSS 260 family

  • Schmersal safety controllers/relays

  • Schmersal series-diagnostic accessories

Alternative product assessment

Schmersal RSS260-I2-D-ST yerine muadil ancak güncel resmi verilerle elektriksel/mekanik/arayüz/çevresel/fonksiyonel ve gerekiyorsa emniyet/Ex eşdeğerliği kanıtlanırsa değerlendirilir. Marka/seri benzerliği tek başına yeterli değildir.

Technical documents

Open data sheets and manufacturer sources. Links open in a new tab.

Frequently asked questions

Schmersal RSS260-I2-D-ST hangi uygulamalarda kullanılır?

Başlıca kullanım alanları: Koruyucu kapı konum izleme, Seri bağlı emniyet sensör zinciri, Manipülasyona dayanıklı RFID emniyet algılama, Makine koruyucu interlock izleme. Nihai seçim gerçek saha koşullarıyla doğrulanmalıdır.

Teknik değerlerin kaynağı nedir?

Teknik değerler güncel resmi üretici kaynağından doğrulandı: https://products.schmersal.com/en_IO/rss260-i2-d-st-103003607

Muadil ürün kullanılabilir mi?

Muadil yalnız elektriksel, mekanik, haberleşme, çevresel, fonksiyonel ve gerekiyorsa emniyet/Ex şartları resmi verilerle eşdeğer olduğunda değerlendirilmelidir.

Montaj öncesi ne doğrulanmalı?

Besleme, arayüz, mekanik ölçüler, çevresel koşullar, bağlantı standardı ve üreticinin güncel talimatları doğrulanmalıdır.

Automation hangi desteği sağlar?

Teknik ürün seçimi, uygulama değerlendirmesi, entegrasyon, devreye alma ve endüstriyel teknik servis için proje bazlı destek ve teklif süreci yürütülebilir.

Related industries & technical tags

Industries

Attributes

Tags

Technical verification note

Before ordering, confirm application suitability, safety functions, connections and revision differences against the exact product code and manufacturer documentation.

Request a product quote

The product is linked automatically. Share your quantity, application and required date.

Product for quotation Schmersal RSS260-I2-D-ST 103003607 RFID Emniyet Sensörü · RSS260-I2-D-ST
RSS260-I2-D-STRequest quote ↗
AUTOMATION / COMPARE

Compare products

Stored specifications are shown side by side, without asserting equivalence or compatibility. Up to 100 fields are shown; check the product page for complete data.

TECHNICAL SOURCING REQUEST

Your quote list

Collect products and quantities. Pricing and lead time are provided after reviewing your request. Your list is stored in this browser.

Continue to quote form →