Technical description and application scope
ifm O5D100 technical overview
Verified technical specifications, selection, installation and commissioning notes for ifm O5D100, with Automation engineering and technical-service support.
Verified technical data
- Model: O5D100
- Type: O5DLCPKG/US
- Measurement principle: Time-of-flight laser
- Measuring range: 0.03…2 m
- Outputs: 2 digital PNP, complementary NO/NC
- Switching frequency: 11 Hz
- Supply: 10…30 VDC
- IO-Link: 1.1, COM2 38.4 kBaud
- Laser class: 2
- Light: red, 650 nm
- Connector: M12 A-coded, 4 contacts
- Protection: IP65 / IP67
- Weight: 61.6 g
Selection and application
Confirm 0.03…2 m measuring range and PNP complementary outputs. Check laser Class 2 requirements and target/background geometry. Use IO-Link 1.1 only where project architecture requires parameter/diagnostic exchange. Verify IP65/IP67 and -25…+60 °C conditions at the installation point.
Installation, commissioning and maintenance
Use the current ifm scale drawing for 56 x 18.2 x 46.8 mm housing and mounting-hole geometry. Keep the optical path free from contamination and avoid mounting stress. Use suitable M12 A-coded cabling and observe laser safety labeling/instructions. Set switch points from the display/buttons or validated IO-Link parameter set. Verify detection across black/white target conditions and actual background distance. Test both digital outputs and IO-Link process data where used. Keep the optical window clean without scratching the lens. Inspect M12 cable/connector and mounting alignment. Revalidate switch-point performance after mechanical changes or lens contamination events.
Source policy: Numeric technical values are taken only from the current official manufacturer product page or official technical documentation. No price, stock, lead-time, warranty or distributor claim is included.