ACS180-04S-03A7-1 combines 0.55 kW nominal power with single-phase 230 V input. The 70 mm R0 width is relevant to auxiliary drives in restricted cabinets. Comparing motor current with the 3.7 A nominal reference makes selection more concrete than power alone.
Selection for your application
Add required mounting clearances to device width when planning the cabinet.
Technical specifications
| Model | ACS180-04S-03A7-1 |
|---|---|
| ABB ordering code | 3AXD50000716579 |
| Nominal supply | 230 V AC, 1 phase |
| Nominal motor power Pn | 0.55 kW |
| Nominal output current In | 3.7 A |
| Frame | R0 |
| Ingress protection | IP20 |
| Width x height x depth | 70 mm x 209 mm x 143 mm |
Pn/In are nominal ratings. Assess heavy-duty capacity and ambient conditions separately.
Is 70 mm the complete installation-space requirement?
It is the device width; ventilation and mounting clearances must be allowed separately.
Request a quotation
Send available space and motor nameplate for 03A7-1 pricing.
Confirm price, stock and lead time for the selected model.