Schmersal AZM300Z-ST-1P2P-A 103001450 RFID Safety Interlock
An RFID-based AZM300 safety interlock using power-to-lock operation, monitored guard locking and two fail-safe digital outputs.
Verified technical specifications, selection, installation and commissioning notes for Schmersal AZM300Z-ST-1P2P-A, with Automation engineering and technical-service support.
Verified technical data
- Coding: Universal RFID coding; low coding level to EN ISO 14119
- Lock principle: Power to lock
- Fail-safe outputs: 2
- Connector: M12, 8-pole, A-coded
- Holding force Fzh: 1150 N
- Holding force Fmax: 1500 N
- Mechanical lifetime: ≥1,000,000 operations (general specification)
- Safety interlocking: Up to PL e / Cat. 4 / SIL 3
- Guard locking: Up to PL d / Cat. 2 / SIL 2
- Supply: 24 VDC -15%/+10%
- Protection: IP66 / IP67 / IP69
Selection criteria
Confirm power-to-lock behavior is appropriate for the risk assessment and escape concept. Validate interlocking PL e/SIL 3 and guard-locking PL d/SIL 2 functions in the complete safety design. Check 1150 N Fzh holding force against door/application loads. Confirm M12 8-pin interface, actuator geometry and environmental conditions.
Installation, commissioning and maintenance
Use two M6 fixing screws at the documented torque and maintain actuator alignment. Install the actuator/guard so the device is not used as an unintended mechanical end stop beyond manufacturer conditions. Validate guard open/closed, lock/unlock, fault and restart behavior. Perform required safety-function validation and document diagnostics. Periodically inspect actuator alignment, mechanical wear and safety diagnostics. Include functional proof testing in the machine safety maintenance plan.
Source policy: Numeric technical claims are taken only from current official manufacturer sources. No price, stock, lead-time, warranty, distributor or partnership claim is included.