MR373 is the three-stage motorised option for the foot-mounted M37 housing. For variable-speed operation, specify the lowest continuous speed as well as the nominal operating point. Motor cooling and gearbox duty should be assessed across that range before selecting the drive package.
Selection for your machine
Provide minimum and maximum speeds and the load at each point.
Technical references
| Model code | MR373 |
|---|---|
| Housing group | M37 |
| Gear type | Helical |
| Stages | 3 |
| Input connection | Directly motor-coupled; motor selection required |
| Output / mounting | Foot mounted, solid output shaft |
| Standard output shaft diameter/length (mm) | Ø40/80 |
| Housing-group nominal torque (Nm, reference) | 820 |
This is a base model record. Select ratio, motor or input interface and mounting position when ordering. Housing torque is a reference, not a guaranteed configured output. Price, stock and lead time require confirmation.
Does an inverter remove the need to check cooling?
No. Cooling at low motor speed must be assessed; a separate fan may be required by the application.
Request a quotation
Review motor options for your MR373 speed range.
Original manufacturer family image; the exact housing size and motor may differ.
Official series page · Manufacturer manual